1.
Int J Comput Assist Radiol Surg ; 14(11): 1945-1953, 2019 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-31502194

RESUMEN

PURPOSE: (1) To improve the accuracy of global and regional alveolar-recruitment quantification in CT scan pairs by accounting for lung-tissue displacements and deformation, (2) To propose a method for local-recruitment calculation. METHODS: Recruitment was calculated by subtracting the quantity of non-aerated lung tissues between expiration and inspiration. To assess global recruitment, lung boundaries were first interactively delineated at inspiration, and then they were warped based on automatic image registration to define the boundaries at expiration. To calculate regional recruitment, the lung mask defined at inspiration was cut into pieces, and these were also warped to encompass the same tissues at expiration. Local-recruitment map was calculated as follows: For each voxel at expiration, the matching location at inspiration was determined by image registration, non-aerated voxels were counted in the neighborhood of the respective locations, and the voxel count difference was normalized by the neighborhood size. The methods were evaluated on 120 image pairs of 12 pigs with experimental acute respiratory distress syndrome. RESULTS: The dispersion of global- and regional-recruitment values decreased when using image registration, compared to the conventional approach neglecting tissue motion. Local-recruitment maps overlaid onto the original images were visually consistent, and the sum of these values over the whole lungs was very close to the global-recruitment estimate, except four outliers. CONCLUSIONS: Image registration can compensate lung-tissue displacements and deformation, thus improving the quantification of alveolar recruitment. Local-recruitment calculation can also benefit from image registration, and its values can be overlaid onto the original image to display a local-recruitment map. They also can be integrated over arbitrarily shaped regions to assess regional or global recruitment.


Asunto(s)
Pulmón/diagnóstico por imagen , Síndrome de Dificultad Respiratoria/diagnóstico , Tomografía Computarizada por Rayos X/métodos , Animales , Modelos Animales de Enfermedad , Porcinos
2.
JACC Cardiovasc Imaging ; 12(1): 123-132, 2019 01.
Artículo en Inglés | MEDLINE | ID: mdl-29778857

RESUMEN

OBJECTIVES: The aim of this study was to develop a new scoring system based on thoracic aortic calcification (TAC) to predict 1-year cardiovascular and all-cause mortality. BACKGROUND: A calcified aorta is often associated with poor prognosis after transcatheter aortic valve replacement (TAVR). A risk score encompassing aortic calcification may be valuable in identifying poor TAVR responders. METHODS: The C4CAPRI (4 Cities for Assessing CAlcification PRognostic Impact) multicenter study included a training cohort (1,425 patients treated using TAVR between 2010 and 2014) and a contemporary test cohort (311 patients treated in 2015). TAC was measured by computed tomography pre-TAVR. CAPRI risk scores were based on the linear predictors of Cox models including TAC in addition to comorbidities and demographic, atherosclerotic disease and cardiac function factors. CAPRI scores were constructed and tested in 2 independent cohorts. RESULTS: Cardiovascular and all-cause mortality at 1 year was 13.0% and 17.9%, respectively, in the training cohort and 8.2% and 11.8% in the test cohort. The inclusion of TAC in the model improved prediction: 1-cm3 increase in TAC was associated with a 6% increase in cardiovascular mortality and a 4% increase in all-cause mortality. The predicted and observed survival probabilities were highly correlated (slopes >0.9 for both cardiovascular and all-cause mortality). The model's predictive power was fair (AUC 68% [95% confidence interval [CI]: 64% to 72%]) for both cardiovascular and all-cause mortality. The model performed similarly in the training and test cohorts. CONCLUSIONS: The CAPRI score, which combines the TAC variable with classical prognostic factors, is predictive of 1-year cardiovascular and all-cause mortality. Its predictive performance was confirmed in an independent contemporary cohort. CAPRI scores are highly relevant to current practice and strengthen the evidence base for decision making in valvular interventions. Its routine use may help prevent futile procedures.


Asunto(s)
Aorta Torácica/diagnóstico por imagen , Enfermedades de la Aorta/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Aortografía/métodos , Angiografía por Tomografía Computarizada , Tomografía Computarizada Multidetector , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Calcificación Vascular/diagnóstico por imagen , Anciano , Anciano de 80 o más Años , Enfermedades de la Aorta/mortalidad , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/mortalidad , Estenosis de la Válvula Aórtica/fisiopatología , Causas de Muerte , Femenino , Francia , Humanos , Masculino , Valor Predictivo de las Pruebas , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento , Calcificación Vascular/mortalidad
3.
J Med Eng ; 2013: 471682, 2013.
Artículo en Inglés | MEDLINE | ID: mdl-27006915

RESUMEN

An MR acquisition protocol and a processing method using distributed computing on the European Grid Infrastructure (EGI) to allow 3D liver perfusion parametric mapping after Magnetic Resonance Dynamic Contrast Enhanced (MR-DCE) imaging are presented. Seven patients (one healthy control and six with chronic liver diseases) were prospectively enrolled after liver biopsy. MR-dynamic acquisition was continuously performed in free-breathing during two minutes after simultaneous intravascular contrast agent (MS-325 blood pool agent) injection. Hepatic capillary system was modeled by a 3-parameters one-compartment pharmacokinetic model. The processing step was parallelized and executed on the EGI. It was modeled and implemented as a grid workflow using the Gwendia language and the MOTEUR workflow engine. Results showed good reproducibility in repeated processing on the grid. The results obtained from the grid were well correlated with ROI-based reference method ran locally on a personal computer. The speed-up range was 71 to 242 with an average value of 126. In conclusion, distributed computing applied to perfusion mapping brings significant speed-up to quantification step to be used for further clinical studies in a research context. Accuracy would be improved with higher image SNR accessible on the latest 3T MR systems available today.

4.
Rev. colomb. radiol ; 23(3): 3521-3528, sept. 2012.
Artículo en Español | LILACS | ID: lil-656539

RESUMEN

En este artículo se presenta un software de código abierto, llamado CreaTools, cuyo principal objetivo es el procesar y facilitar la visualización de imágenes médicas. Este software flexible funciona en diferentes sistemas operativos (Linux, Mac OS X, Windows), se desarrolla en el lenguaje de programación C++ para asegurar una fácil integración de módulos C++ y proporciona a los usuarios herramientas computacionales para construir interfaces gráficas de usuario (GUI), incluidos los datos de entrada/salida (manejo de archivos), la visualización, la interacción y el procesamiento de datos. Este artículo muestra también la utilidad de CreaTools mediante un proyecto de investigación que consiste en la detección automática de lesiones arteriales. Los algoritmos desarrollados han sido implementados en una interfaz gráfica amigable con visualización 3D e interacción. Ejemplos de tales algoritmos incluyen la extracción de ejes de arterias y la generación de modelos descriptivos de arterias con lesiones y sin lesiones.


Asunto(s)
Anomalías Cardiovasculares , Vasos Coronarios , Procesamiento de Imagen Asistido por Computador
SELECCIÓN DE REFERENCIAS